0096522958111

Logo

Find A programme

Operation and Maintenance of Circuit Breakers and Switchgears

Dates Venues Register
11/01/2026 - 15/01/2026 DUBAI

Introduction

Operation and Maintenance of Circuit Breakers and Switchgears

Course Objectives

This course is designed to enable participants to:

  • List the voltage convention classifications used in this course.
  • Describe switchgear construction.
  • Describe a ground fault relay system.
  • Describe the three basic types of low and medium voltage circuit breaker contacts.
  • Describe the molded case circuit breaker.

Course Outlines

General Introduction

  • Electrical engineering basic concepts
  • Three phase review and per unit
  • Voltage levels
  • One line and three line diagram
  • Generation system layout
  • Transmission system layout
  • Substation system layout
  • Distribution system layout

Industrial Switchgears

  • Fuses
  • Auto-reclosers
  • Automatic sectionalizer
  • Circuit Breakers
  • Isolator switches
  • Load switches
  • Relays
  • Current transformers
  • Voltage transformers

CB Design Specification Based on Short Circuit Current Level

  • Per unit system
  • Faults on power systems
  • Transient phenomena in power system.
  • Symmetrical component analysis of three phase network
  • Network connection for various fault types
  • Current and voltage distribution in system due to a fault
  • Effect of system on zero sequence quantities
  • Computer programs based short circuit calculation.

CB Design Specification Based on Arc Phenomena and Circuit Interruption

  • Arc phenomena
  • Maintenance of the Arc
  • Properties of Arc
  • Arc Interruption theory
  • Circuit Breaker Rating
  • Circuit constants and circuit conditions
  • Conditions of severity
  • Restriking voltage transient
  • Class A ultra fast transients
  • Class B system transients
  • Class C low transients
  • Transmission line transient
  • Switching transients
  • Duties of Switchgear

LV Circuit Breakers

  • Low voltage molded case current limiting circuit breakers
  • Low voltage molded case circuit breakers with high breaking capacity
  • Insulated case circuit breakers
  • Low voltage air circuit breakers
  • Low voltage circuit breakers specification

Modern MV and HV Vacuum CB

  • Introduction
  • Advantages of vacuum interruption
  • Vacuum contactors and interrupters
  • The vacuum medium
  • The vacuum arc
  • Vacuum arc stability
  • Vacuum break down
  • Vacuum switch construction
  • Applications of vacuum circuit breakers

Modern MV and HV SF6 CB Introduction

  • Basic Features of SF6 Breakers
  • Dielectric properties of SF6
  • Quenching properties of SF6
  • Construction of SF6 breaker
  • SF6 CB types
  • Puffer type SF6 breakers
  • Double Pressure System
  • Single Pressure Puffer-Piston System
  • Single Pressure Self Blast System
  • Improvement in SF6 Breakers for HV

Other Type of Circuit Breakers

Air Circuit Breakers

  • Method of increasing arc resistance
  • Plan break type
  • Magnetic blow out type
  • Arc splitter type
  • Application
  • Construction and operation
  • Axial air CB
  • Blast air CB

Oil Circuit Breakers

  • Arc rupture under oil
  • Advantages of oil
  • Disadvantages of oil
  • Plan break oil circuit breakers
  • Arc control circuit oil breakers
  • Minimum oil circuit breakers
  • Construction and operation

Dc Circuit Breakers

  • Construction
  • Methods of interruption
  • Application

Circuit Breaker Inspection, Maintenance and Services

  • Inspection
  • General inspection technical procedure
  • Daily inspection of circuit breakers
  • Monthly inspection of circuit breakers
  • Annual inspection of circuit breakers
  • Disassembly
  • Cleaning
  • Tightening
  • Lubrication
  • Equipments used in testing
  • Testing procedure
  • Direct testing
  • Contact resistance test.
  • Insulation resistance test
  • Test report
  • Indirect testing
  • One hour Video, HV CB Maintenance and Repair)

Circuit Breakers Control, Protection and Testing

  • Switchgears control devices and wiring
  • Switchgears protection devices and wiring
  • Testing Classification
  • Testing laboratories
  • Description of a simple testing station

CB Troubleshooting

  • Low insulation Resistance (below 2000 Mega-ohms) between a) Phase terminal and earthed frame, with breaker closed b) Phase terminals of a pole.
  • Resistance between Termi¬nals of Pole too high (above 100 microhms) (15 micro-ohm per joint) contact
  • Unequal contact Wipe and Travel in 3-pole Measured from top surface of inter¬rupter flange and the contact lip by a simple rod with a) breaker open and b) breaker closed
  • One of the pole docs not close.

Make an enquiry about seminar

Live chat by BoldChat